Evertz EQX-XPTG-576X576 576X576 Crosspoint LP

Product Details

The EQX platform is Evertz® flagship routing & distribution solution designed for high availability by adopting extensive industry leading redundancy for all critical system elements. With its time proven robustness and redundancy, the EQX is ideal for mission critical and demanding 24/7 environments.

The EQX26 platform has the ability to route up to 576×576 signals all in a compact 26RU frame, in addition to the 576 outputs the EQX26-FRQT-XLINK2 come with 18 X-Link connections. The EQX26 frame offers the ability to scale up to 1152 x 1152 system without requiring complex, expensive external splitting or active DA-ing of sources and the combining and switching of destinations. Providing peace of mind that the EQX can expand beyond the constraints of a single frame as ones application change and grow. All these factors and more makes the EQX26 most suitable for applications like network and local broadcasters, mobile production, cable, military, government and corporate applications.

Manufacturer Specs

ConfigurationExcluding frame XLINK outputs
576×576 (1152 available) in 26RU
PSU separate 1RU
Inputs & Outputs: Selectable in blocks of 18
Redundant Protection
Redundant Crosspoint
Redundant Frame Controller
Redundant Power Supply
Redundant Cooling Fans
Video Inputs
Formats SMPTE 259M, 292M, 310M, 424M, ASI, 10G
Optical Formats SMPTE 292M, GLINK, any optical signal between 3MB/s and 3GB/s
Signal Level 800mV p-p
Impedance 75Ω terminating
Return Loss > 15dB typical (5 – 1500MHz) /
> 10dB typical (1.5 – 3GHz)
Cable Equalization Belden 1694A @ 270MHz 300m to 500m
Belden 1694A @ 1.5GHz 100m to 200m
Belden 1694A @ 3GHz 90m to 150m
Connectors BNC IEC 61169.8 Annex A
Video Outputs
Signals Supported SMPTE 259M, 292M, 310M, 424M, ASI, 10G
Reclocking Configurable
Non-reclocking Configurable
Impedance 75Ω terminating
Return Loss > 15dB typical (5 – 1500MHz) /
> 10dB typical (1.5 – 3GHz)
DC Offset 0 ±0.5V
Output Jitter 0.2UI
Connectors BNC IEC 61169.8 Annex A
Fiber Inputs/Outputs
SFP1R-2 Dual Optical SFP Receiver, Up to 3GB/s
Connector LC/PC
Operating Wavelength 1270nm to 1610nm
Maximum Input Power -1dBm
Optical Sensitivity -21dBm±1dBm
SFP1T13-2 Dual Optical SFP Transmitter, Up to 3GB/s, 1310nm
Connector LC/PC
Wavelengths 1310nm
Output Power -2dBm ±1dBm
Reference Timing
Switching Reference Analog 525/625/tri-level HD looping connections
Connector 2 BNC IEC 61169.8 Annex A
Signal Level 1V p-p ±3dB
Impedance 75Ω terminating (active loop out optional)
Reference Timing 4 independent timing planes, programmable output by output
Control
Q-Link 4 X 75Ω video cable (maximum length 500m)
Serial RS-422/232 4 X D9 female
Ethernet 10/100baseT, 4 X RJ45
Physical
Height 45.5″(115.5cm), 26RU
Width 19″ (48.3cm), 19″ Rack Mount
Depth 19.4″ (49.3cm) over hinges and BNCs
Power
Voltage Auto ranging 100 to 240V 50/60Hz
Up to 4 load sharing PS modules in 1RU frame
Separate main input for each module or external 48V DC
Power 1200 watts per PS module
2100 watts for a Green 26RU populated as a 576×576
Redundancy Separate 1RU frame with up to 4 PS modules for 1:1 redundancy available

Product Details

The EQX platform is Evertz® flagship routing & distribution solution designed for high availability by adopting extensive industry leading redundancy for all critical system elements. With its time proven robustness and redundancy, the EQX is ideal for mission critical and demanding 24/7 environments.

The EQX26 platform has the ability to route up to 576×576 signals all in a compact 26RU frame, in addition to the 576 outputs the EQX26-FRQT-XLINK2 come with 18 X-Link connections. The EQX26 frame offers the ability to scale up to 1152 x 1152 system without requiring complex, expensive external splitting or active DA-ing of sources and the combining and switching of destinations. Providing peace of mind that the EQX can expand beyond the constraints of a single frame as ones application change and grow. All these factors and more makes the EQX26 most suitable for applications like network and local broadcasters, mobile production, cable, military, government and corporate applications.

Manufacturer Specs

ConfigurationExcluding frame XLINK outputs
576×576 (1152 available) in 26RU
PSU separate 1RU
Inputs & Outputs: Selectable in blocks of 18
Redundant Protection
Redundant Crosspoint
Redundant Frame Controller
Redundant Power Supply
Redundant Cooling Fans
Video Inputs
Formats SMPTE 259M, 292M, 310M, 424M, ASI, 10G
Optical Formats SMPTE 292M, GLINK, any optical signal between 3MB/s and 3GB/s
Signal Level 800mV p-p
Impedance 75Ω terminating
Return Loss > 15dB typical (5 – 1500MHz) /
> 10dB typical (1.5 – 3GHz)
Cable Equalization Belden 1694A @ 270MHz 300m to 500m
Belden 1694A @ 1.5GHz 100m to 200m
Belden 1694A @ 3GHz 90m to 150m
Connectors BNC IEC 61169.8 Annex A
Video Outputs
Signals Supported SMPTE 259M, 292M, 310M, 424M, ASI, 10G
Reclocking Configurable
Non-reclocking Configurable
Impedance 75Ω terminating
Return Loss > 15dB typical (5 – 1500MHz) /
> 10dB typical (1.5 – 3GHz)
DC Offset 0 ±0.5V
Output Jitter 0.2UI
Connectors BNC IEC 61169.8 Annex A
Fiber Inputs/Outputs
SFP1R-2 Dual Optical SFP Receiver, Up to 3GB/s
Connector LC/PC
Operating Wavelength 1270nm to 1610nm
Maximum Input Power -1dBm
Optical Sensitivity -21dBm±1dBm
SFP1T13-2 Dual Optical SFP Transmitter, Up to 3GB/s, 1310nm
Connector LC/PC
Wavelengths 1310nm
Output Power -2dBm ±1dBm
Reference Timing
Switching Reference Analog 525/625/tri-level HD looping connections
Connector 2 BNC IEC 61169.8 Annex A
Signal Level 1V p-p ±3dB
Impedance 75Ω terminating (active loop out optional)
Reference Timing 4 independent timing planes, programmable output by output
Control
Q-Link 4 X 75Ω video cable (maximum length 500m)
Serial RS-422/232 4 X D9 female
Ethernet 10/100baseT, 4 X RJ45
Physical
Height 45.5″(115.5cm), 26RU
Width 19″ (48.3cm), 19″ Rack Mount
Depth 19.4″ (49.3cm) over hinges and BNCs
Power
Voltage Auto ranging 100 to 240V 50/60Hz
Up to 4 load sharing PS modules in 1RU frame
Separate main input for each module or external 48V DC
Power 1200 watts per PS module
2100 watts for a Green 26RU populated as a 576×576
Redundancy Separate 1RU frame with up to 4 PS modules for 1:1 redundancy available